- Sedenak Industrial Park Sedenak Johor Malaysia 81000

Lokasi Kerja
Penerangan Kerja
Kelayakan
The individual whom we seek should possess the following:
Degree in any Engineering / Science / Facilities Management or other technical field of study
Highly analytical and possess strong fundamentals and comprehension of Thermodynamics and Fluid Mechanics
Possesses at least 8 years of O&M experience handling ACMV systems in critical facilities (preferably Electrical and Electronics) or 5 years in other facilities
Highly familiar with O&M related MEPF system jargons (eg, HT and LV, RMU, MSB/SSB/DB, TX, etc) and units of measurement (eg, PPM, V, Ohm, A, etc)
Self-driven, innovative and independently drive assigned tasks to satisfactory completion in an output-based environment. Proactive in identifying issues and developing solutions to overcome them
Ability to be on standby and respond outside of office hours
Highly adept with MS Office suite (Word, Excel, PowerPoint)
Proficient in Mandarin (Speaking, Reading, Writing)
Tanggungjawab
Job Overview
In this role, the successful applicant will function as part of the on-site team to ensure timely and quality deliverables of services rendered by OCS to its Client. The successful applicant will function as the focal point accountable for Electrical Systems that cover:
Switchboards: Medium Voltage (11kV) and Low Voltage (415V) distribution system including ATS, Transformers and Switchgears (note: B0 chargeman available on-site)
Critical DC equipment: UPS, Batteries
Generators: Load bank testing, off load testing, functionality and interfacing with other auxiliary components such as exhaust dampers
Protection Systems: Lightning protection system, Earth protection system
Building Electrical Systems: Electrical DBs, lighting, street lighting, emergency lighting, EV Chargers
Key Responsibilities / Accountabilities
Comply with Client’s process flows on PPM and Reactive Maintenance (RM).
Develop and/or review Method of Procedure (MOPs) document for equipment and/or systems for which PPM or RM is to be executed. This will require close collaboration with both internal team members and with Client representative(s).
Manage, track and ensure timely deliverables of both OCS appointed and managed (i.e, Client’s vendor who is assigned to OCS to manage) vendors.
Collaborate closely with internal team members to ensure internal (OCS) and external (Client) documentation processes are adhered to at all times, In particular, this will require close collaboration with the CMMS Engineer and Admin Executive of OCS at site.
Actively participate in any shutdown and/or major activity that may only be allowed to take place on weekends or on Public Holidays.
Prepare daily/ weekly updates and monthly report summaries as necessary. This will require daily site walks and verification (refer point no. 5 above) as part of the preparation process.
Repair and perform preventive maintenance on afore-listed electrical equipment.
Troubleshoot defective equipment and maintain a snags list of defects that cover specific issues and proposed rectification plans.
Perform daily inspections of the critical equipment.
Supports incident response and mitigation. Prepare Root Cause Analysis (RCA) reports and corrective action
Coordinate with client and vendor for safe execution of any electrical change.
Evaluate vendor proposals for electrical services, parts and PPM works.
Plan manpower to support PPM and others improvement projects.
Monitor critical power, distribution and support systems and facilities to meet or exceed up-time service levels.
Manfaat
Kemahiran
Peringatan Penting
Jangan pernah kongsikan maklumat bank atau kad kredit anda semasa memohon pekerjaan. Elakkan membuat sebarang pembayaran atau mengisi survey yang tidak berkaitan. Jika ada yang mencurigakan, sila laporkan iklan pekerjaan ini segera.